10
2. Water Supply and Drain Connections
To prevent damage to the freezer mechanism, do not operate this icemaker when the water
supply is OFF, or if the pressure is below the recommended minimum water pressure of 10 PSIG
(0.7 bar). Stop the icemaker until proper water pressure is resumed.
WARNING
• Water supply inlet is 1/2" FPT and must be connected only to a potable water supply.
• A water supply line shut-o valve and drain valve must be installed.
• Water supply pressure should be a minimum of 10 PSIG (0.7 bar) and a maximum of 113 PSIG (7.5 bar). If the
pressure exceeds 113 PSIG (7.5 bar), use a pressure reducing valve.
• Drain outlet is 1/2" FPT.
• For gravity drain installation, drain must be 1/4" fall per foot (2 cm fall per meter) on horizontal runs to get
good ow.
• An air gap of a minimum of 2 vertical inches (5 vertical cm) should be between the end of the drain pipe and
the oor drain.
• The drain pipe must be installed properly to prevent a backow into the storage bin.
• For condensate pump installation, refer to the instruction manual included with the pump.
• A plumbing permit and services of a licensed plumber may be required in some areas.
• This icemaker should be installed in accordance with applicable national, state and local regulations.
To approved oor drain
Fig. 1
Icemaker
Shut-O Valve
Drain Valve
Water Supply Inlet
1/2" FPT
Drain Outlet
1/2" FPT
1/4" fall per foot